Summary

This bill amends Statewide Amendments Incorporated as Part of State Construction Code.

What it does

  • This bill:
  • amends a provision of the International Building Code to provide that an individual who performs fireproof coating may obtain certain certification;
  • amends a provision of the International Residential Code regarding when a drainage system is not required; and
  • makes technical and conforming changes.

Every vote on this bill

2/27/2018Senate Comm - Substitute Recommendation from # 0 to # 1
Senate Business and Labor Committee
5 0 3not eligible / no record
2/27/2018Senate Comm - Favorable Recommendation
Senate Business and Labor Committee
6 0 2not eligible / no record
3/1/2018Senate/ circled
Senate 2nd Reading Calendar
Voice votenot eligible / no record
3/1/2018Senate/ uncircled
Senate 2nd Reading Calendar
Voice votenot eligible / no record
3/1/2018Senate/ floor amendment # 1
Senate 2nd Reading Calendar
Voice votenot eligible / no record
3/1/2018Senate/ passed 2nd reading
Senate 3rd Reading Calendar
25 0 4not eligible / no record
3/2/2018Senate/ passed 3rd reading
Clerk of the House
23 0 6not eligible / no record
3/8/2018House/ passed 3rd reading
House Speaker
68 0 7YEA

Bill text

enrolled version · official source
STATE BUILDING CODE AMENDMENTS
GENERAL SESSION
STATE OF UTAH
Chief Sponsor: Karen Mayne
House Sponsor: 
Mike Schultz
LONG TITLE
General Description:
This bill amends Statewide Amendments Incorporated as Part of State Construction
Code.
Highlighted Provisions:
This bill:
▸ amends a provision of the International Building Code to provide that an individual
who performs fireproof coating may obtain certain certification;
▸ amends a provision of the International Residential Code regarding when a drainage
system is not required; and
▸ makes technical and conforming changes.
Money Appropriated in this Bill:
None
Other Special Clauses:
None
Utah Code Sections Affected:
AMENDS:
15A-3-104
, as last amended by Laws of Utah 2016, Chapter 249
15A-3-202
, as last amended by Laws of Utah 2017, Chapter 236
Be it enacted by the Legislature of the state of Utah:
Section 1. Section 
15A-3-104
 is amended to read:
15A-3-104.
Amendments to Chapters 7 through 9 of IBC.
(1) In IBC, Section 704.13.2, the following sentence is added to the end of the section:
"An individual spraying fire-resistant materials may obtain a certificate that demonstrates that
the individual has undergone training on how to spray fire-resistant materials to manufacturer's
specifications."
[
(1)
] 
(2)
 IBC, Section (F)901.8, is deleted and replaced with the following: "(F)901.8
Pump and riser room size. Fire pump and automatic sprinkler system riser rooms shall be
designed with adequate space for all installed equipment necessary for the installation and to
provide sufficient working space around the stationary equipment. Clearances around
equipment shall be in accordance with manufacturer requirements and not less than the
following minimum elements:
901.8.1 A minimum clear and unobstructed distance of 12-inches shall be provided from the
installed equipment to the elements of permanent construction.
901.8.2 A minimum clear and unobstructed distance of 12-inches shall be provided between
all other installed equipment and appliances.
901.8.3 A clear and unobstructed width of 36-inches shall be provided in front of all installed
equipment and appliances, to allow for inspection, service, repair or replacement without
removing such elements of permanent construction or disabling the function of a required
fire-resistance-rated assembly.
901.8.4 Automatic sprinkler system riser rooms shall be provided with a clear and
unobstructed passageway to the riser room of not less than 36-inches, and openings into the
room shall be clear and unobstructed, with doors swinging in the outward direction from the
room and the opening providing a clear width of not less than 34-inches and a clear height of
the door opening shall not be less than 80-inches.
901.8.5 Fire pump rooms shall be provided with a clear and unobstructed passageway to the
fire pump room of not less than 72-inches, and openings into the room shall be clear,
unobstructed and large enough to allow for the removal of the largest piece of equipment, with
doors swinging in the outward direction from the room and the opening providing a clear width
of not less than 68-inches and a clear height of the door opening shall not be less than
80-inches."
[
(2)
] 
(3)
 In IBC, Section (F)903.2.2, the words "the entire floor" are deleted and
replaced with "a building" and the last paragraph is deleted.
[
(3)
] 
(4)
 IBC, Section (F)903.2.4, condition 2, is deleted and replaced with the
following: "2. A Group F-1 fire area is located more than three stories above the lowest level
of fire department vehicle access."
[
(4)
] 
(5)
 IBC, Section (F)903.2.7, condition 2, is deleted and replaced with the
following: "2. A Group M fire area is located more than three stories above the lowest level of
fire department vehicle access."
[
(5)
] 
(6)
 IBC, Sections (F)903.2.8, (F)903.2.8.1, (F)903.2.8.2, and (F)903.2.8.4, are
deleted and replaced with the following: "(F)903.2.8 Group R. An automatic sprinkler system
installed in accordance with Section 903.3 shall be provided throughout all buildings with a
Group R fire area.
Exceptions:
1. Detached one- and two-family dwellings and multiple single-family dwellings (townhouses)
constructed in accordance with the International Residential Code For One- and Two-Family
Dwellings.
2. Single story Group R-1 occupancies with fire areas not more than 2,000 square feet that
contain no installed plumbing or heating, where no cooking occurs, and constructed of Type
I-A, I-B, II-A, or II-B construction."
[
(6)
] 
(7)
 IBC, Sections (F)903.2.8.3 and (F)903.2.8.3.1, are renumbered to (F)903.2.8.1
and (F)903.2.8.1.1.
[
(7)
] 
(8)
 IBC, Section (F)903.2.8.3.2, is renumbered to (F)903.2.8.1.2 and the
following exception is added:
"Exception: Group R-4 fire areas not more than 4,500 gross square feet and not containing
more than 16 residents, provided the building is equipped throughout with an approved fire
alarm system that is interconnected and receives its primary power from the building wiring
and a commercial power system."
[
(8)
] 
(9)
 IBC, Section (F)903.2.8.4, is deleted.
[
(9)
] 
(10)
 IBC, Section (F)903.2.9, condition 2, is deleted and replaced with the
following: "2. A Group S-1 fire area is located more than three stories above the lowest level
of fire department vehicle access."
[
(10)
] 
(11)
 IBC, Section (F)904.12, is deleted and replaced with the following: "
(F)904.12 Commercial cooking systems. The automatic fire-extinguishing system for
commercial cooking systems shall be of a type recognized for protection of commercial
cooking equipment and exhaust systems. Pre-engineered automatic extinguishing systems
shall be tested in accordance with UL 300 and listed and labeled for the intended application. 
The system shall be installed in accordance with this code, its listing and the manufacturer's
installation instructions.
Exception: Factory-built commercial cooking recirculating systems that are tested in
accordance with UL 710B and listed, labeled, and installed in accordance with Section 304.1 of
the International Mechanical Code."
[
(11)
] 
(12)
 IBC, Sections (F)904.12.3, (F)904.12.3.1, (F)904.12.4, and (F)904.12.4.1,
are deleted.
[
(12)
] 
(13)
 In IBC, Section 905, a new subsection, Section (F)905.3.9, is added as
follows:
"Open Parking Garages. Open parking garages shall be equipped with an approved
Class 1 manual standpipe system when fire department access is not provided for firefighting
operations to within 150 feet of all portions of the open parking garage as measured from the
approved fire department vehicle access. Class 1 manual standpipe shall be accessible
throughout the parking garage such that all portions of the parking structure are protected
within 150 feet of a hose connection."
[
(13)
] 
(14)
 In IBC, Section (F)905.8, the exception is deleted and replaced with the
following:
"Exception: Where subject to freezing and approved by the fire code official."
[
(14)
] 
(15)
 In IBC, Section (F)907.2.3 Group E, the first sentence is deleted and
rewritten as follows: "A manual fire alarm system that activates the occupant notification
system in accordance with Section (F)907.5 shall be installed, in accordance with Section
(F)907.6 and administrative rules made by the State Fire Prevention Board in Group E
occupancies."
[
(15)
] 
(16)
 IBC, Sections (F)915 through (F)915.6, are deleted and replaced with the
following:
"(F)915 Where required.
Group I-1, I-2, I-4, and R occupancies located in a building containing a fuel-burning appliance
or in a building that has an attached garage shall be equipped with single-station carbon
monoxide alarms. The carbon monoxide alarms shall be listed as complying with UL 2034 or
UL 2075 and be installed and maintained in accordance with NFPA 720 and the manufacturer's
instructions. An open parking garage, as defined in Chapter 2, or an enclosed parking garage,
ventilated in accordance with Section 404 of the International Mechanical Code, shall not be
considered an attached garage. A minimum of one carbon monoxide alarm shall be installed
on each habitable level.
(F)915.1 Interconnection.
Where more than one carbon monoxide alarm is required to be installed within Group I-1, I-2,
I-4, or R occupancies, the carbon monoxide alarm shall be interconnected in such a manner that
the activation of one alarm will activate all of the alarms. Physical interconnection of carbon
monoxide alarms shall not be required where listed wireless alarms are installed and all alarms
sound upon activation of one alarm. The alarm shall be clearly audible in all bedrooms over
background noise levels with all intervening doors closed.
(F)915.2 Power source.
In new construction, required carbon monoxide alarms shall receive their primary power from
the building wiring where such wiring is served from a commercial source and shall be
equipped with a battery backup. Carbon monoxide alarms with integral strobes that are not
equipped with a battery backup shall be connected to an emergency electrical system. Carbon
monoxide alarms shall emit a signal when the batteries are low. Wiring shall be permanent and
without a disconnecting switch other than as required for overcurrent protection.
Exceptions.
1. Carbon monoxide alarms are not required to be equipped with a battery backup where they
are connected to an emergency electrical system.
2. Hard wiring of carbon monoxide alarms in existing areas shall not be required where the
alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing
the structure, unless there is an attic, crawl space, or basement available that could provide
access for hard wiring without the removal of interior finishes.
(F)915.3 Group E.
A carbon monoxide detection system shall be installed in new buildings that contain Group E
occupancies in accordance with IFC, Chapter 9, Section 915. A carbon monoxide detection
system shall be installed in existing buildings that contain Group E occupancies in accordance
with IFC, Chapter 11, Section 1103.9.
(F)915.3.1 Where required.
In Group E occupancies, a carbon monoxide detection system shall be provided where a
fuel-burning appliance, a fuel-burning fireplace, or a fuel-burning forced air furnace is present.
(F)915.3.2 Detection equipment.
Each carbon monoxide detection system shall be installed in accordance with NFPA 720 and
the manufacturer's instructions and be listed as complying with, for single station detectors, UL
2034 and, for system detectors, UL 2075.
(F)915.3.3 Locations.
Each carbon monoxide detection system shall be installed in the locations specified in NFPA
720.
(F)915.3.4 Combination detectors.
A combination carbon monoxide/smoke detector is an acceptable alternative to a carbon
monoxide detection system if the combination carbon monoxide/smoke detector is listed in
accordance with UL 2075 and UL 268.
(F)915.3.5 Power source.
Each carbon monoxide detection system shall receive primary power from the building wiring
if the wiring is served from a commercial source. If primary power is interrupted, each carbon
monoxide detection system shall receive power from a battery. Wiring shall be permanent and
without a disconnecting switch other than that required for overcurrent protection.
(F)915.3.6 Maintenance.
Each carbon monoxide detection system shall be maintained in accordance with NFPA 720. A
carbon monoxide detection system that becomes inoperable or begins to produce end of life
signals shall be replaced."
Section 2. Section 
15A-3-202
 is amended to read:
15A-3-202.
Amendments to Chapters 1 through 5 of IRC.
(1) In IRC, Section R102, a new Section R102.7.2 is added as follows: "R102.7.2
Physical change for bedroom window egress. A structure whose egress window in an existing
bedroom is smaller than required by this code, and that complied with the construction code in
effect at the time that the bedroom was finished, is not required to undergo a physical change to
conform to this code if the change would compromise the structural integrity of the structure or
could not be completed in accordance with other applicable requirements of this code,
including setback and window well requirements."
(2) In IRC, Section 109:
(a) A new IRC, Section 109.1.5, is added as follows: "R109.1.5 Weather-resistant
exterior wall envelope inspections. An inspection shall be made of the weather-resistant
exterior wall envelope as required by Section R703.1 and flashings as required by Section
R703.8 to prevent water from entering the weather-resistive barrier."
(b) The remaining sections are renumbered as follows: R109.1.6 Other inspections;
R109.1.6.1 Fire- and smoke-resistance-rated construction inspection; R109.1.6.2 Reinforced
masonry, insulating concrete form (ICF) and conventionally formed concrete wall inspection;
and R109.1.7 Final inspection.
(3) IRC, Section R114.1, is deleted and replaced with the following: "R114.1 Notice to
owner. Upon notice from the building official that work on any building or structure is being
prosecuted contrary to the provisions of this code or other pertinent laws or ordinances or in an
unsafe and dangerous manner, such work shall be immediately stopped. The stop work order
shall be in writing and shall be given to the owner of the property involved, or to the owner's
agent or to the person doing the work; and shall state the conditions under which work will be
permitted to resume."
(4) In IRC, Section R202, the following definition is added: "CERTIFIED
BACKFLOW PREVENTER ASSEMBLY TESTER: A person who has shown competence to
test Backflow prevention assemblies to the satisfaction of the authority having jurisdiction
under Utah Code, Subsection 
19-4-104
(4)."
(5) In IRC, Section R202, the definition for "CONDITIONED SPACE" is modified by
deleting the words at the end of the sentence "being heated or cooled by any equipment or
appliance" and replacing them with the following: "enclosed within the building thermal
envelope that is directly heated or cooled, or indirectly heated or cooled by any of the following
means:
1. Openings directly into an adjacent conditioned space.
2. An un-insulated floor, ceiling or wall adjacent to a conditioned space.
3. Un-insulated duct, piping or other heat or cooling source within the space."
(6) In IRC, Section R202, the definition of "Cross Connection" is deleted and replaced
with the following: "CROSS CONNECTION. Any physical connection or potential
connection or arrangement between two otherwise separate piping systems, one of which
contains potable water and the other either water of unknown or questionable safety or steam,
gas, or chemical, whereby there exists the possibility for flow from one system to the other,
with the direction of flow depending on the pressure differential between the two systems (see
"Backflow, Water Distribution")."
(7) In IRC, Section 202, in the definition for gray water a comma is inserted after the
word "washers"; the word "and" is deleted; and the following is added to the end: "and clear
water wastes which have a pH of 6.0 to 9.0; are non-flammable; non-combustible; without
objectionable odors; non-highly pigmented; and will not interfere with the operation of the
sewer treatment facility."
(8) In IRC, Section R202, the definition of "Potable Water" is deleted and replaced
with the following: "POTABLE WATER. Water free from impurities present in amounts
sufficient to cause disease or harmful physiological effects and conforming to the Utah Code,
Title 19, Chapter 4, Safe Drinking Water Act, and Title 19, Chapter 5, Water Quality Act, and
the regulations of the public health authority having jurisdiction."
(9) IRC, Figure R301.2(5), is deleted and replaced with Table R301.2(5a) and Table
R301.2(5b) as follows:
"TABLE NO. R301.2(5a)
STATE OF UTAH - REGIONAL SNOW LOAD FACTORS
COUNTY
Po
S
Ao
Beaver
6.2
Box Elder
5.2
Cache
4.5
Carbon
5.2
Daggett
6.5
Davis
4.5
Duchesne
6.5
Emery
6.0
Garfield
6.0
Grand
6.5
Iron
5.8
Juab
5.2
Kane
5.7
Millard
5.3
Morgan
4.5
Piute
6.2
Rich
4.1
Salt Lake
4.5
San Juan
6.5
Sanpete
5.2
Sevier
6.0
Summit
5.0
Tooele
4.5
Uintah
7.0
Utah
4.5
Wasatch
5.0
Washington
6.0
Wayne
6.5
Weber
4.5
TABLE NO. R301.2(5b)
REQUIRED SNOW LOADS FOR SELECTED UTAH CITIES AND TOWNS1,2
The following jurisdictions require design snow load values that differ from the Equation in
the Utah Snow Load Study.
County
City
Elevation
Ground Snow
Load (psf)
Roof Snow
Load (psf) 6
Carbon
Price3
All other county locations5
--
--
--
Davis
Fruit Heights3
- 4850
Emery
Green River3
Garfield
Panguitch3
Rich
Woodruff3
Laketown4
Garden City5
Randolph4
--
--
--
San Juan
Monticello3
Summit
Coalville3
Kamas4
Tooele
Tooele3
Utah
Orem3
Pleasant Grove4
Provo5
--
--
--
Wasatch
Heber5
--
--
--
Washington
Leeds3
Santa Clara3
St. George3
All other county locations5
--
--
--
Wayne
Loa3
1The IRC requires a minimum live load -- See R301.6.
2This table is informational only in that actual site elevations may vary. Table is only valid
if site elevation is within 100 feet of the listed elevation. Otherwise, contact the local
Building Official.
3Values adopted from Table VII of the Utah Snow Load Study
4Values based on site-specific study. Contact local Building Official for additional
information.
5Contact local Building Official.
6Based on Ce =1.0, Ct =1.0 and Is =1.0"
(10) IRC, Section R301.6, is deleted and replaced with the following: "R301.6 Utah
Snow Loads. The snow loads specified in Table R301.2(5b) shall be used for the jurisdictions
identified in that table. Otherwise, the ground snow load, Pg, to be used in the determination
of design snow loads for buildings and other structures shall be determined by using the
following formula: Pg = (Po2 + S2(A-Ao)2)0.5 for A greater than Ao, and Pg = Po for A less
than or equal to Ao.
WHERE:
Pg = Ground snow load at a given elevation (psf);
Po = Base ground snow load (psf) from Table No. R301.2(5a);
S = Change in ground snow load with elevation (psf/100 ft.) From Table No. R301.2(5a);
A = Elevation above sea level at the site (ft./1,000);
Ao = Base ground snow elevation from Table R301.2(5a) (ft./1,000).
The building official may round the roof snow load to the nearest 5 psf. The ground snow
load, Pg, may be adjusted by the building official when a licensed engineer or architect submits
data substantiating the adjustments.
Where the minimum roof live load in accordance with Table R301.6 is greater than the design
roof snow load, such roof live load shall be used for design, however, it shall not be reduced to
a load lower than the design roof snow load. Drifting need not be considered for roof snow
loads less than 20 psf."
(11) In IRC, Section R302.5.1, the words "self-closing device" are deleted and replaced
with "self-latching hardware".
(12) IRC, Section R302.13, is deleted.
(13) In IRC, Section R303.4, the number "5" is changed to "3" in the first sentence.
(14) IRC, Sections R311.7.4 through R311.7.5.3, are deleted and replaced with the
following: "R311.7.4 Stair treads and risers. R311.7.5.1 Riser height. The maximum riser
height shall be 8 inches (203 mm). The riser shall be measured vertically between leading
edges of the adjacent treads. The greatest riser height within any flight of stairs shall not
exceed the smallest by more than 3/8 inch (9.5 mm).
R311.7.5.2 Tread depth. The minimum tread depth shall be 9 inches (228 mm). The tread
depth shall be measured horizontally between the vertical planes of the foremost projection of
adjacent treads and at a right angle to the tread's leading edge. The greatest tread depth within
any flight of stairs shall not exceed the smallest by more than 3/8 inch (9.5 mm). Winder
treads shall have a minimum tread depth of 10 inches (254 mm) measured as above at a point
12 inches (305 mm) from the side where the treads are narrower. Winder treads shall have a
minimum tread depth of 6 inches (152 mm) at any point. Within any flight of stairs, the
greatest winder tread depth at the 12-inch (305 mm) walk line shall not exceed the smallest by
more than 3/8 inch (9.5 mm).
R311.7.5.3 Profile. The radius of curvature at the leading edge of the tread shall be no greater
than 9/16 inch (14.3 mm). A nosing not less than 3/4 inch (19 mm) but not more than 1 1/4
inches (32 mm) shall be provided on stairways with solid risers. The greatest nosing projection
shall not exceed the smallest nosing projection by more than 3/8 inch (9.5 mm) between two
stories, including the nosing at the level of floors and landings. Beveling of nosing shall not
exceed 1/2 inch (12.7 mm). Risers shall be vertical or sloped from the underside of the leading
edge of the tread above at an angle not more than 30 degrees (0.51 rad) from the vertical. Open
risers are permitted, provided that the opening between treads does not permit the passage of a
4-inch diameter (102 mm) sphere.
Exceptions.
1. A nosing is not required where the tread depth is a minimum of 10 inches (254 mm).
2. The opening between adjacent treads is not limited on stairs with a total rise of 30 inches
(762 mm) or less."
(15) IRC, Section R312.2, is deleted.
(16) IRC, Sections R313.1 through R313.2.1, are deleted and replaced with the
following: "R313.1 Design and installation. When installed, automatic residential fire
sprinkler systems for townhouses or one- and two-family dwellings shall be designed and
installed in accordance with Section P2904 or NFPA 13D."
(17) In IRC, Section 315.3, the following words are added to the first sentence after the
word "installed": "on each level of the dwelling unit and".
(18) In IRC, Section R315.5, a new exception, 3, is added as follows:
"3. Hard wiring of carbon monoxide alarms in existing areas shall not be required where the
alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing
the structure, unless there is an attic, crawl space or basement available which could provide
access for hard wiring, without the removal of interior finishes."
(19) A new IRC, Section R315.7, is added as follows: " R315.7 Interconnection. 
Where more than one carbon monoxide alarm is required to be installed within an individual
dwelling unit in accordance with Section R315.1, the alarm devices shall be interconnected in
such a manner that the actuation of one alarm will activate all of the alarms in the individual
unit. Physical interconnection of smoke alarms shall not be required where listed wireless
alarms are installed and all alarms sound upon activation of one alarm.
Exception: Interconnection of carbon monoxide alarms in existing areas shall not be required
where alterations or repairs do not result in removal of interior wall or ceiling finishes exposing
the structure, unless there is an attic, crawl space or basement available which could provide
access for interconnection without the removal of interior finishes."
(20) In IRC, Section R403.1.6, a new Exception 3 is added as follows: " 3. When
anchor bolt spacing does not exceed 32 inches (813 mm) apart, anchor bolts may be placed
with a minimum of two bolts per plate section located not less than 4 inches (102 mm) from
each end of each plate section at interior bearing walls, interior braced wall lines, and at all
exterior walls."
(21) In IRC, Section R403.1.6.1, a new exception is added at the end of Item 2 and
Item 3 as follows: "Exception: When anchor bolt spacing does not exceed 32 inches (816 mm)
apart, anchor bolts may be placed with a minimum of two bolts per plate section located not
less than 4 inches (102 mm) from each end of each plate section at interior bearing walls,
interior braced wall lines, and at all exterior walls."
(22) In IRC, Section R404.1, a new exception is added as follows: "Exception: As an
alternative to complying with Sections R404.1 through R404.1.5.3, concrete and masonry
foundation walls may be designed in accordance with IBC Sections 1807.1.5 and 1807.1.6 as
amended in Section 1807.1.6.4 and Table 1807.1.6.4 under these rules."
(23) In IRC, Section R405.1, a new exception is added as follows: "Exception: When a
geotechnical report has been provided for the property, a drainage system is not required unless
the drainage system is required as a condition of the geotechnical report. 
The geological report
shall make a recommendation regarding a drainage system.
"